TT-N-97D
TABLE V. Test methods.
Test |
ASTM standard |
FED-STD-141 test method |
Paragraph |
Specific gravity @ 20C/20C |
D 891 |
||
Flash point |
D 56 |
||
Aniline point |
D 611 |
||
Mixed aniline point |
D 611 |
||
Distillation |
D 1078 |
||
Color |
D 156 |
||
Nonvolatile matter |
D 1353 |
||
Appearance |
4261 |
||
Odor |
D 1296 |
4.4.3.1 |
|
Copper corrosion |
D 130 |
||
Doctor test |
D 235 |
||
Spot test |
4.4.3.2 |
||
Water test |
D 1476 |
||
Acidity |
D 847 |
||
Residue |
D 1093 |
||
Stability |
4.4.3.3 |
4.4.3.1 Odor. The residual odor of the naphtha shall be determined after the filter paper has been allowed to dry at standard conditions (see 4.4.2) for 24 hours.
4.4.3.2 Spot test.
4.4.3.2.1 Apparatus. No. 2 Whatman or equal 12.5 cm in diameter filter paper.
4.4.3.2.2 Procedure. Transfer five drops of the sample by means of a small pipette or burette to the center of a No. 2 Whatman (or equivalent) filter paper, 12.5 centimeters (cm) in diameter support on a 7-cm crystallizing dish and allow the liquid to evaporate at 21 °C to 32 °C (69.8 °F to 89.6 °F), away from direct sunlight and strong drafts. Examine the paper visually for the presence of any stain or residual oiliness after 30 minutes.
4.4.3.3 Stability.
4.4.3.3.1 Apparatus. The apparatus shall consist of a glass container such as an 8-ounce oil bottle, a suitable metal bomb to hold the glass container at the required pressures, and a water or a steam bath.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business